A ranch is the hardest common house to size correctly: big surface area for its square footage, long exterior walls, and heat loss spread thin across a single story. The old boiler was almost certainly sized by rule of thumb — frequently two to three times the building's actual heat loss — and a like-for-like replacement repeats the error. An oversized boiler short-cycles against a ranch's thermal mass: blast, satisfy, shut off, repeat. Fuel wasted, parts worn, comfort uneven — and on oil, an oversized burner soots up faster between services, which Westbury's oil-heavy streets feel directly.
The fix is a real heat-loss calculation, room by room, counting the actual envelope — including finished basements and garage-adjacent utility rooms in splits, which lose heat differently than the main living space. Colonials are more forgiving, with their compact two-story loss, but the principle holds: size to the building, not to the nameplate of the unit being hauled out. Undersized is rare and obvious; oversized is common and expensive, one fuel bill at a time.