Review symptoms and fault history
Describe whether the boiler tries to ignite, lights briefly, stays in lockout, or fires while the home remains cold. Record the model and fault code if visible without opening the unit.
No heat, a burner that will not start, or a boiler that keeps shutting down? Gas boiler faults can involve ignition, controls, water circulation, or venting. Call to describe the symptoms and ask about repair options in your area.
General inquiries: 7 AM–7 PM · Emergency calls: 24/7
Enter your ZIP code or city to check listed coverage. You can also call to ask about availability.
Online coverage is not confirmed for every location. Search results do not guarantee an appointment.
Not all no-heat complaints come from the gas burner. A boiler that never ignites may have an ignition or flame-proving fault, while a burner that fires but leaves radiators cold may have a circulator, valve, pressure, or control problem. Record visible fault codes and whether ignition starts or stops. Do not remove covers or repeatedly reset a locked-out boiler.
A displayed error code or the point when the boiler shuts down can help narrow the diagnostic process. Do not remove panels or repeatedly reset a boiler that keeps locking out.

Gas boiler troubleshooting involves checking the sequence of operation rather than assuming every no-heat complaint is a burner failure. Only a qualified professional should test gas, combustion, or venting components.
Describe whether the boiler tries to ignite, lights briefly, stays in lockout, or fires while the home remains cold. Record the model and fault code if visible without opening the unit.
A professional may distinguish an ignition failure from poor flame detection, investigate safe venting and combustion, and test pumps or heating controls when the burner operates but heat does not circulate.
Ask what testing identified the fault, whether a part actually failed, whether venting or combustion needs correction, and the proposed diagnostic and repair charges before approving work.
Safety: If you smell gas, leave the building immediately. From a safe location, contact your gas utility or emergency services. Do not operate switches, flames, or the boiler. Never bypass gas or safety controls.
Describe whether the burner fails to ignite, lights and shuts off, or runs without heating radiators. Share any error code so the right type of assessment can be discussed.
Call (888) 766-1474 about ignition faults, no heat or repeated boiler shutdowns.
Share the boiler type, any displayed fault code, and when the problem started.
Provide your city or ZIP code so availability can be checked.
Ask about the assessment, possible fees and scheduling before agreeing to work.
A modern gas boiler is a chain of safeties. A break anywhere in the chain stops heat.
The sequence on a call for heat: the thermostat signals, the fan (inducer) starts and the pressure switch proves the flue is clear, the gas valve opens, the igniter (hot-surface element or spark electrode) lights the gas, and the flame sensor rod proves flame by rectification current. Only then does the boiler run. The PCB (control board) watches every step; any failure drops the boiler into lockout.
Separate from combustion, the sealed heating circuit depends on the expansion tank (a diaphragm tank absorbing pressure rise), the pressure relief valve, the circulator, and on combis the diverter valve. Condensing models add a condensate trap and drain — a blocked trap is one of the most common winter lockout causes.

What the boiler is doing points at where the chain broke.

Answers to common homeowner questions about gas-fired boiler faults, costs and safety.
A lockout means a control has stopped operation after detecting a fault. Ignition failure, lost flame signal, unsafe venting conditions, or other controls may be involved. The displayed code narrows testing but does not prove that a specific part needs replacement.
Use only the reset procedure in your manufacturer’s user instructions. If the fault returns, stop resetting and arrange qualified diagnosis; repeated resets can be unsafe.
Leave the building immediately. From outside and away from the building, contact the gas utility’s emergency line or 911. Do not use switches, a phone indoors, or an ignition source.
If the burner operates but heat does not reach the rooms, a circulator, zone valve, trapped air, low system pressure, or heating-control issue may be involved. These differ from ignition faults and require their own diagnosis.
Costs depend on diagnosis, parts, labor, access and any after-hours charges. Ask about diagnostic fees and request an explanation of the proposed work and price before authorizing repairs.
Not necessarily. A code identifies a detected condition, which may have multiple causes. Component testing is important before replacing parts.
Consider the diagnosed fault, age and condition, parts availability, repeat breakdowns and the cost of a safe repair relative to replacement. Ask for the reasoning behind any recommendation.
Enter your ZIP code in the checker or call (888) 766-1474. Online results may not confirm your area, and scheduling depends on local availability.
That pattern usually means the flame sensor cannot prove the burner lit. The control opens the gas valve, ignition occurs, but with no confirmed flame signal it shuts the valve as a safety response. A dirty or failed flame sensor rod is the common cause; low gas pressure and a failing PCB are less common ones. It is diagnosed by measuring the flame rectification signal, not by replacing parts at random.
No. A lockout means a safety control stopped the boiler for a reason — failed ignition, lost flame, or unsafe venting among them. Repeated resets can mask a developing fault like delayed ignition. Note the error code and call instead of resetting again.

Startup failures, error codes, sensors, and electrical controls.
View Boiler Ignition & Controls Repair →
Water leaks, persistent pressure loss, and pressure fluctuations.
View Boiler Leak & Pressure Repair →
Seasonal inspections and preventive system care.
View Boiler Maintenance →
Combination-boiler heating and domestic hot-water faults.
View Combi Boiler Repair →Call with your ZIP code, boiler model if known, and any displayed fault code. Explain whether the burner fails to start, lights then shuts off, or runs without heating the home. Ask about diagnostic charges and local appointment availability.